Brands |
N/A Performix® |
Dielectric |
N/A 1400 V/mil |
Dielectric Test Method |
N/A American Society for Testing and Materials (ASTM D-149) |
Solids Weight |
N/A 24 % |
Tensile |
N/A 3,740 psi |
Tensile Test Method |
N/A American Society for Testing and Materials (ASTM D-638) |
Elongation |
N/A 430 % |
Elongation Test Method |
N/A American Society for Testing and Materials (ASTM D-638) |
Cut Resistance |
N/A Very Good |
Cut Resistance Test Method |
N/A American Society for Testing and Materials (ASTM D-1044) |
Shelf Life |
N/A 1+ years at 77 ºF unopened container |
Shore A Hardness |
N/A 70 duro |
Salt Spray |
N/A Passed 1,000 hours |
Salt Spray Test Method |
N/A American Society for Testing and Materials (ASTM B-117) |
Weatherability |
N/A 3 to 5 |
Weatherability Test Method |
N/A American Society for Testing and Materials (ASTM G-53) |
Temperature Use Range |
N/A -30 to 200 ºF |
Chemical Resistance |
N/A
Acids, Alkalis, Pollutants - Excellent Petroleums - Limited |
Alternative Products |
N/A Liquid Tape Spray |
|
N/A
Wires, terminals or all other surfaces must be clean, dry, and free of all oils, grease, wax and loose rust. |
|
N/A Allow 4 hours dry time per coat before use. Allow overnight drying whenever possible. Avoid excessive air movement, heat or humidity. Minimal 2 coats required (5+ mils) to assure good dielectric protection. Always use proper ventilation and protection. |
|
N/A
For Industrial Use Only. |