Skip To Content

Catalog

LIQUID TAPE is an air dry synthetic rubber coating that can be easily brushed on and exhibits excellent moisture, acid, alkaline, abrasion and dielectric resistance. LIQUID TAPE is available in red and black will not crack, peel, or harden and remains flexible – even under extreme conditions.
LIQUID TAPE can be used in many applications including electrical connections for boats, trailers, RV’s, trucks, automobiles, timers, pool electricals, bilge pumps, sprinkler pumps, instruments, computers, circuit boards, switches, and will stop terminal screws from vibrating loose. Use LIQUID TAPE to insulate, protect and color code.
Unit of Measure

Technical Specs

Brands

N/A Performix®

Dielectric

N/A 1400 V/mil

Dielectric Test Method

N/A American Society for Testing and Materials (ASTM D-149)

Solids Weight

N/A 24 %

Tensile

N/A 3,740 psi

Tensile Test Method

N/A American Society for Testing and Materials (ASTM D-638)

Elongation

N/A 430 %

Elongation Test Method

N/A American Society for Testing and Materials (ASTM D-638)

Cut Resistance

N/A Very Good

Cut Resistance Test Method

N/A American Society for Testing and Materials (ASTM D-1044)

Shelf Life

N/A 1+ years at 77 ºF unopened container

Shore A Hardness

N/A 70 duro

Salt Spray

N/A Passed 1,000 hours

Salt Spray Test Method

N/A American Society for Testing and Materials (ASTM B-117)

Weatherability

N/A 3 to 5

Weatherability Test Method

N/A American Society for Testing and Materials (ASTM G-53)

Temperature Use Range

N/A -30 to 200 ºF

Chemical Resistance

N/A Acids, Alkalis, Pollutants - Excellent
Petroleums - Limited

Alternative Products

N/A Liquid Tape Spray

Surface Preparations

N/A Wires, terminals or all other surfaces must be clean, dry, and free of all oils, grease, wax and loose rust.

MIX WELL BEFORE USE. USE ADEQUATE VENTILATION:
Stir gently with brush applicator cap to avoid producing bubbles before each use. Apply wet overlapping coats. Allow 10-20 minutes dry time (dry to the touch) before applying additional coats to desired thickness. A minimum of 2-3 coats are recommended for best results. Allow 24 hours to fully cure.

Caution

N/A Turn off power before starting electrical work and follow your local electrical codes.

Hints

N/A Allow 4 hours dry time per coat before use. Allow overnight drying whenever possible. Avoid excessive air movement, heat or humidity. Minimal 2 coats required (5+ mils) to assure good dielectric protection. Always use proper ventilation and protection.

Note

N/A For Industrial Use Only.

We cannot anticipate all conditions under which this information and our products, or the products of other manufacturers in combination with our products, may be used. We accept no responsibility for results obtained by the applications of this information or the safety and suitability of our products, either alone or in combination with other product combination for their own purposes. Unless otherwise agreed in writing, we sell the products without warranty, and buyers and users assume all responsibility and liability for loss or damage arising from the handling and use of our products whether used alone or in combination with other products. Ever changing V.O.C. regulations in your area may require you to contact local authorities for proper use and/or disposal of this product. Should you need further assistance, please contact PLAST DIP INTERNATIONAL technical service.

Performix and logo are registered trademarks of PLASTI DIP INTERNATIONAL